¼¼°èÀÇ °ü»óµ¿¸Æ ¿ìȸ¼ú ÀÌ½Ä ÀåÄ¡ ½ÃÀå : ±â¼úº°, Á¦Ç°º°, ÃÖÁ¾ »ç¿ëÀÚº° ±âȸ ºÐ¼® ¹× »ê¾÷ ¿¹Ãø(2023-2032³â)
Coronary Artery Bypass Grafts Device Market By Technology, By Product, By End Users : Global Opportunity Analysis and Industry Forecast, 2023-2032
»óǰÄÚµå : 1396938
¸®¼­Ä¡»ç : Allied Market Research
¹ßÇàÀÏ : 2023³â 10¿ù
ÆäÀÌÁö Á¤º¸ : ¿µ¹® 259 Pages
 ¶óÀ̼±½º & °¡°Ý (ºÎ°¡¼¼ º°µµ)
US $ 5,730 £Ü 7,917,000
PDF (Business License) help
PDF º¸°í¼­¸¦ 1¸í¸¸ ÀÌ¿ëÇÒ ¼ö ÀÖ´Â ¶óÀ̼±½ºÀÔ´Ï´Ù. Àμâ´Â 5ȸ °¡´ÉÇϸç, Àμ⹰ÀÇ ÀÌ¿ë ¹üÀ§´Â PDF ÀÌ¿ë ¹üÀ§¿Í µ¿ÀÏÇÕ´Ï´Ù. 2¸í ÀÌ»óÀÌ ÀÌ¿ëÇÒ °æ¿ì, Ãß°¡ ¿ä±ÝÀ» ÁöºÒÇÏ¿© ¶óÀ̼±½º ¾÷±×·¹À̵å·Î ÃÖ´ë 5¸í±îÁö ÀÌ¿ë °¡´ÉÇÕ´Ï´Ù.
US $ 9,600 £Ü 13,264,000
PDF (Enterprise User License) & Excel (Data Pack) & Free Update help
PDF º¸°í¼­ ¹× Excel µ¥ÀÌÅ͸¦ µ¿ÀÏ ±â¾÷ÀÇ ¸ðµç ºÐÀÌ ÀÌ¿ëÇÒ ¼ö ÀÖ´Â ¶óÀ̼±½ºÀÔ´Ï´Ù. Àμ⠰¡´ÉÇϸç Àμ⹰ÀÇ ÀÌ¿ë ¹üÀ§´Â PDF ÀÌ¿ë ¹üÀ§¿Í µ¿ÀÏÇÕ´Ï´Ù. º¸°í¼­ ¾÷µ¥ÀÌÆ® ¼­ºñ½º°¡ ¹«·á·Î Á¦°øµË´Ï´Ù.


Çѱ۸ñÂ÷

°ü»óµ¿¸Æ ¿ìȸ¼ú ÀÌ½Ä ÀåÄ¡(Coronary Artery Bypass Grafts Device) ½ÃÀåÀº 2022³â¿¡ 9¾ï 5,927¸¸ ´Þ·¯·Î Æò°¡µÇ¾úÀ¸¸ç, 2023³âºÎÅÍ 2032³â±îÁöÀÇ CAGRÀº 3.7%·Î ÃßÀÌÇÏ¸ç ¼ºÀå ÇÒ °ÍÀ¸·Î ¿¹»óµÇ¸ç, 2032³â¿¡´Â 13¾ï 8,230¸¸ ´Þ·¯¿¡ À̸¦ °ÍÀ¸·Î ¿¹ÃøµË´Ï´Ù.

°ü»óµ¿¸Æ ¿ìȸ¼ú À̽Ä(CABG) ÀåÄ¡´Â °ü»óµ¿¸Æ ÁúȯÀÇ ¼ö¼ú Ä¡·á¿¡ Áß¿äÇÑ ¿ªÇÒÀ» ÇÕ´Ï´Ù. °ü»óµ¿¸Æ ÁúȯÀº ½ÉÀå ±ÙÀ°¿¡ Ç÷¾×À» °ø±ÞÇÏ´Â Ç÷°üÀÌ ÇöóÅ©°¡ ½×¿© Á¼¾ÆÁö°Å³ª ¸·È÷´Â ÁúȯÀÔ´Ï´Ù. °ü»óµ¿¸Æ ¿ìȸ¼úÀº ¸·È÷°Å³ª Á¼¾ÆÁø °ü»óµ¿¸ÆÀ» °Ç°­ÇÑ Ç÷°üÀ¸·Î ¿ìȸÇÏ¿© ½ÉÀå ±ÙÀ°¿¡ ÃæºÐÇÑ Ç÷·ù¸¦ °ø±ÞÇϱâ À§ÇØ ½ÃÇàÇÏ´Â ¼ö¼úÀÔ´Ï´Ù. ÀϹÝÀûÀ¸·Î ¿ÂÆßÇÁ¿Í ¿ÀÇÁÆßÇÁ´Â µÎ °¡Áö À¯ÇüÀÇ CABG ¼ö¼ú ÀýÂ÷À̸ç, ¿ÂÆßÇÁ °ü»óµ¿¸Æ ¿ìȸ¼úÀÇ °æ¿ì ½ÉÆó ¿ìȸ ȸ·Î¿Í Á¤ÁöµÈ ½ÉÀåÀ» »ç¿ëÇÏ¿© ¼ö¼úÇÑ´Ù´Â Â÷ÀÌÁ¡ÀÌ ÀÖ½À´Ï´Ù. ¹Ý¸é¿¡ ¿ÀÇÁ ÆßÇÁ °ü»óµ¿¸Æ ¿ìȸ¼ú¿¡¼­´Â ¿Ü°úÀǰ¡ ½ÉÀåÀÌ ¶Ù´Â »óÅ¿¡¼­ ¼ö¼úÇÕ´Ï´Ù.

°ü»óµ¿¸Æ ¿ìȸ¼ú ÀÌ½Ä ÀåÄ¡ ½ÃÀåÀÇ ¼ºÀåÀ» À̲ô´Â ÁÖ¿ä ¿äÀÎÀº °ü»ó µ¿¸Æ ½ÉÀå Áúȯ(CHD) ¹ßº´ À§ÇèÀÌ ÀÖ´Â ³ëÀÎ Àα¸ÀÇ Áõ°¡¿Í Á×»ó µ¿¸Æ °æÈ­Áõ°ú °°Àº °ü·Ã »óŰ¡ ³ªÀ̰¡ µé¸é¼­ Å©°Ô Áõ°¡Çϱ⠶§¹®ÀÔ´Ï´Ù. ¶ÇÇÑ »ýȰ ½À°ü º¯È­, ¾É¾ÆÀÖ´Â ½À°ü, °Ç°­¿¡ ÇØ·Î¿î ½Ä½À°ü, ½ºÆ®·¹½º ¼öÁØ Áõ°¡·Î ÀÎÇÑ °ü»ó µ¿¸Æ ½ÉÀå ÁúȯÀÇ À¯º´·ü ±ÞÁõµµ ½ÃÀåÀÇ ¼ºÀåÀ» ÁÖµµ ÇÒ °ÍÀ¸·Î ¿¹»óµË´Ï´Ù. ³ªÀ̰¡ µé¾î°¨¿¡ µû¶ó °ü»óµ¿¸Æ Áúȯ(CAD) ¹× °ü·Ã ½ÉÀå ¹®Á¦°¡ ¹ß»ýÇÒ À§ÇèÀÌ Å©°Ô Áõ°¡ÇÕ´Ï´Ù. °ü»óµ¿¸Æ ÁúȯÀº °ü»óµ¿¸Æ¿¡ ÇöóÅ©°¡ ½×¿© ½ÉÀå ±ÙÀ°À¸·Î °¡´Â Ç÷·ù°¡ °¨¼ÒÇÏ´Â °ÍÀ» Ư¡À¸·Î ÇÏ´Â Àü ¼¼°èÀûÀ¸·Î ³Î¸® ÆÛÁø ÁúȯÀÔ´Ï´Ù. ¿¹¸¦ µé¾î, ¹Ì±¹ ½ÉÀå ÇùȸÀÇ 2023³â º¸°í¼­¿¡ µû¸£¸é ù ¹øÂ° ½ÉÀå ¸¶ºñ°¡ ¹ß»ýÇÑ Æò±Õ ¿¬·ÉÀº ³²¼º 65.6¼¼, ¿©¼º 72.0¼¼·Î ÃßÁ¤µË´Ï´Ù.

°ü»óµ¿¸Æ ¿ìȸ¼ú À̽ÄÀº ½ÉÇÑ °ü»óµ¿¸Æ ÁúȯÀÇ Ä¡·á¿¡ »ç¿ëµÇ´Â Áß¿äÇÑ ¼ö¼ú ÁßÀçÀÔ´Ï´Ù. °ü»óµ¿¸Æ ¿ìȸ¼úÀº Æó»ö ¶Ç´Â ÇùÂøµÈ °ü»óµ¿¸ÆÀ» ¿ìȸÇϱâ À§ÇØ ½ÅüÀÇ ´Ù¸¥ ºÎºÐ¿¡¼­ °Ç°­ÇÑ Ç÷°üÀ» À̽ÄÇÏ¿© ´ëü Ç÷¾× °æ·Î¸¦ ¸¸µé°í ½ÉÀåÀ¸·ÎÀÇ ÀûÀýÇÑ Ç÷·ù¸¦ ȸº¹½Ãŵ´Ï´Ù. ³ë³â Àα¸°¡ °ü»óµ¿¸Æ Áúȯ°ú °ü·Ã ½ÉÇ÷°ü Áúȯ¿¡ °É¸®±â ½±±â ¶§¹®¿¡ °ü»óµ¿¸Æ ¿ìȸ¼ú À̽ļú ¹× °ü·Ã Àåºñ¿¡ ´ëÇÑ ¼ö¿ä°¡ ±ÞÁõÇϰí ÀÖ½À´Ï´Ù. ¶ÇÇÑ, ³ëÀεéÀº Á¾Á¾ ¿©·¯ º´Á¸ ÁúȯÀ» ¾Î°í ÀÖÀ¸¸ç, ħ½ÀÀûÀÌ°í º¹ÀâÇÑ ¼ö¼ú¿¡ ºñÇØ °ü»óµ¿¸Æ ¿ìȸ¼ú ÀÌ½Ä ¼ö¼úÀÇ ÀÌ»óÀûÀÎ Èĺ¸ÀÚÀÔ´Ï´Ù. °á·ÐÀûÀ¸·Î, °ü»óµ¿¸Æ Áúȯ¿¡ ´ëÇÑ ÀÌȯÀ²ÀÌ ³ôÀº ³ëÀÎ Àα¸ Áõ°¡´Â °ü»óµ¿¸Æ ¿ìȸ¼ú ÀÌ½Ä ÀåÄ¡ ½ÃÀå ¼ºÀåÀÇ ¸Å¿ì Áß¿äÇÑ ¿øµ¿·ÂÀÌ µÇ¾ú½À´Ï´Ù.

¸ñÂ÷

Á¦1Àå ¼­·Ð

Á¦2Àå ÁÖ¿ä ¿ä¾à

Á¦3Àå ½ÃÀå °³¿ä

Á¦4Àå °ü»óµ¿¸Æ ¿ìȸ¼ú ÀÌ½Ä ÀåÄ¡ ½ÃÀå : ±â¼úº°

Á¦5Àå °ü»óµ¿¸Æ ¿ìȸ¼ú ÀÌ½Ä ÀåÄ¡ ½ÃÀå : Á¦Ç°º°

Á¦6Àå °ü»óµ¿¸Æ ¿ìȸ¼ú ÀÌ½Ä ÀåÄ¡ ½ÃÀå : ÃÖÁ¾ »ç¿ëÀÚº°

Á¦7Àå °ü»óµ¿¸Æ ¿ìȸ¼ú ÀÌ½Ä ÀåÄ¡ ½ÃÀå : Áö¿ªº°

Á¦8Àå °æÀï ±¸µµ

Á¦9Àå ±â¾÷ °³¿ä

LYJ
¿µ¹® ¸ñÂ÷

¿µ¹®¸ñÂ÷

The coronary artery bypass grafts device market was valued at $959.27 million in 2022 and is estimated to reach $1,382.30 million by 2032, exhibiting a CAGR of 3.7% from 2023 to 2032. The global coronary artery bypass grafts device market was valued at $0.96 billion in 2022, and is projected to reach $1.38 billion by 2032, growing at a CAGR of 3.7% from 2023 to 2032.

Coronary artery bypass graft (CABG) device plays an important role in the surgical treatment of coronary artery disease. Coronary artery disease is a condition where the blood vessels supplying blood to the heart muscles become narrowed or blocked due to the buildup of plaque. Coronary artery bypass graft is a surgical procedure which is carried out to restore adequate blood flow to the heart muscles by bypassing the blocked or narrowed coronary arteries with healthy blood vessels. In general, on-pump and off-pump are the two types of CABG surgical procedures with the difference being the use of a cardiopulmonary bypass circuit and an arrested heart to operate during an on-pump coronary artery bypass graft. On the other hand, during off-pump coronary artery bypass graft, the surgeons operates on the beating heat.

The key factors driving the growth of the coronary artery bypass graft devices market are rise in geriatric population as they have the risk of developing coronary heart disease (CHD) and related conditions such as atherosclerosis increases significantly with age. Furthermore, surge in prevalence of coronary heart diseases owing to lifestyle changes, sedentary habits, unhealthy diets, and increase in stress levels is also expected to drive the growth of the market. As people age, their risk of developing coronary artery disease (CAD) and related cardiac issues significantly increases. Coronary artery disease is a prevalent condition worldwide, characterized by the accumulation of plaque in the coronary arteries, leading to reduced blood flow to the heart muscle. For instance, according to a 2023 report by American Heart Association, it was estimated that the average age at the first heart attack was 65.6 years for males and 72.0 years for females.

Coronary artery bypass grafting is a crucial surgical intervention used to treat severe coronary artery disease. It involves the creation of alternative blood pathways by grafting healthy blood vessels from other parts of the body to bypass the blocked or narrowed coronary arteries, thereby restoring proper blood flow to the heart. As the geriatric population is more prone to coronary artery disease and related cardiovascular problems, the demand for coronary artery bypass graft procedures and associated devices has surged. Furthermore, the elderly often have multiple comorbidities, making them ideal candidates for coronary artery bypass graft surgeries as compared to more invasive or complex procedures. In conclusion, the escalating geriatric population, with its higher susceptibility to coronary artery disease, has become a pivotal driver for the growth of the coronary artery bypass graft devices market.

In addition, surge in prevalence of coronary heart disease is expected to act as a significant driver for the coronary artery bypass graft devices market. The bypass restores the blood flow to the ischemic myocardium which, in turn, restores function, viability, and relieves anginal symptoms. The global burden of coronary heart disease has been on the rise, primarily attributed to lifestyle factors such as sedentary lifestyles, unhealthy diets, and increasing rates of obesity. For instance, according to a 2023 report by U.S. National library of medicine, it was estimated that globally almost 400,000 coronary artery bypass grafting surgeries are performed each year making it the most commonly performed major surgical procedure. Thus, the surge in the prevalence of coronary heart disease is expected to drive the growth of the coronary artery bypass graft devices market.

However, high cost of procedures might act as restraint for the coronary artery bypass graft devices market. The high cost of coronary artery bypass graft surgery makes it less accessible to individuals without adequate health insurance coverage. The cost of devices, hospital stays, and post-operative care be a significant financial burden for patients.

The coronary artery bypass graft devices market is segmented on the basis of technology, product, end user, and region. By technology, the market is categorized into off-pump, on-pump, and minimally invasive CABG. By product, the market is classified into cardiopulmonary bypass machines, endoscopic vessel harvesting systems, heart positioners, tissue stabilizer and others. By end user, the market is divided into hospitals, cardiac centers, and others. Region-wise, the market is analyzed across North America (the U.S., Canada, and Mexico), Europe (Germany, France, the UK, Italy, Spain, and rest of Europe), Asia-Pacific (Japan, China, Australia, India, South Korea, and rest of Asia-Pacific), and LAMEA (Brazil, South Africa, Saudi Arabia, and rest of LAMEA).

Major key players that operate in the global coronary artery bypass graft devices market are Medtronic, Baxter International Inc, Terumo Corporation, Teleflex Incorporated, Peters Surgical Group, Getinge AB, Genesee Biomedical Inc, Transonic Systems Inc., Saphena Medical, Inc. and Condor MedTec GmbH.

Key Benefits for Stakeholders

Additional benefits you will get with this purchase are:

Possible Customization with this report (with additional cost and timeline, please talk to the sales executive to know more)

Key Market Segments

By End Users

By Technology

By Product

By Region

Key Market Players:

TABLE OF CONTENTS

CHAPTER 1: INTRODUCTION

CHAPTER 2: EXECUTIVE SUMMARY

CHAPTER 3: MARKET OVERVIEW

CHAPTER 4: CORONARY ARTERY BYPASS GRAFTS DEVICE MARKET, BY TECHNOLOGY

CHAPTER 5: CORONARY ARTERY BYPASS GRAFTS DEVICE MARKET, BY PRODUCT

CHAPTER 6: CORONARY ARTERY BYPASS GRAFTS DEVICE MARKET, BY END USERS

CHAPTER 7: CORONARY ARTERY BYPASS GRAFTS DEVICE MARKET, BY REGION

CHAPTER 8: COMPETITIVE LANDSCAPE

CHAPTER 9: COMPANY PROFILES

(ÁÖ)±Û·Î¹úÀÎÆ÷¸ÞÀÌ¼Ç 02-2025-2992 kr-info@giikorea.co.kr
¨Ï Copyright Global Information, Inc. All rights reserved.
PC¹öÀü º¸±â